Quick Answer: What Dimensions Should Be Checked on a Knife Gate Valve?
Knife gate valve dimensions are not a single fixed chart. For engineering selection, replacement or RFQ review, the dimensions should be checked as a complete dimensional package, including face-to-face length, flange data, bolt-hole pattern, bore or port size, overall height, open height, stroke, actuator envelope, width and approximate weight.
The most important point is that a knife gate valve dimension table or PDF is usually only a preliminary reference. Final dimensions can change depending on valve size, connection type, flange standard, pressure class, seat design, actuator configuration and manufacturer construction.
Before procurement or replacement, confirm the dimensions from the valve datasheet, GA drawing or certified drawing. If only one dimension is checked, or if a preliminary chart is treated as the final reference, the project may face pipe gap mismatch, flange bolt-hole misalignment, installation clearance problems, field rework or schedule delay.
For replacement projects, also compare the existing valve tag, face-to-face length, flange drilling and available installation space. This article explains how to read knife gate valve dimensions, how to check face-to-face length and flange data, and what information to send before requesting a confirmed drawing.
If your main question is valve size, bore selection or flow capacity rather than dimensional envelope, use the knife gate valve sizing guide as a separate reference before finalizing the drawing data.
Key Knife Gate Valve Dimension Fields
A knife gate valve drawing normally includes more than one “main size.” Different fields answer different engineering questions. Some dimensions affect pipe fit, some affect bolting, and others affect installation clearance.
The table below is not a complete knife gate valve dimensions chart. It is a reading map that shows which dimensional fields should be reviewed on a datasheet, GA drawing, dimension table or certified drawing.
Common Dimension Fields
| Dimension field | What it means | Where to find it | Why it matters | What to confirm |
|---|---|---|---|---|
| DN / NPS | Nominal valve size | Datasheet, nameplate, drawing | Basic pipeline size reference | Confirm it matches the pipe size |
| Face-to-face length | Distance between connection faces | GA drawing, dimension table | Determines pipe spool / replacement fit | Confirm standard and manufacturer design |
| Flange OD | Outside diameter of flange or connection face | Drawing, flange standard | Affects pipe flange match | Confirm flange standard |
| Bolt circle | Diameter of bolt-hole circle | Drawing, flange data | Determines bolting alignment | Confirm BCD and bolt pattern |
| Bolt holes | Quantity and diameter of holes | Drawing, flange table | Determines installation fit | Confirm hole number and size |
| Bore / port | Flow opening through valve | Datasheet, drawing | Affects flow passage and solids handling | Confirm full port or reduced port if relevant |
| Overall height | Total height of valve assembly | GA drawing | Affects installation space | Confirm with selected actuator |
| Open height | Height when valve is fully open | GA drawing | Affects overhead clearance | Confirm stem / gate travel |
| Stroke / gate travel | Travel distance of gate or blade | Drawing, actuator data | Affects open / close movement | Confirm actuator stroke |
| Actuator envelope | Space occupied by handwheel, cylinder or actuator | GA drawing | Affects layout and access | Confirm manual / pneumatic / electric / hydraulic type |
| Width | Lateral envelope of valve body or actuator | GA drawing | Affects side clearance | Confirm adjacent equipment clearance |
| Weight | Approximate mass of assembly | Datasheet, drawing | Affects handling, support and shipping | Confirm final weight after actuator selection |

A dimension chart is useful only when the valve construction is already clear. If the connection style, actuator type or flange standard changes, the dimensional package can also change.
The most common dimension-checking mistakes are:
- checking only face-to-face length while ignoring flange drilling and bolt-hole pattern;
- checking closed height but not open height, stem travel or actuator envelope;
- using generic catalogue data instead of the exact GA drawing or certified drawing for the selected configuration.
These mistakes are especially common in replacement work, where the new valve must fit an existing pipe gap and existing flange arrangement.
Face-to-Face Dimension Explained
The face-to-face dimension is the distance between the two connection faces of the valve. For knife gate valves, this is one of the most important dimensions for replacement, pipe spool design and installation space review.
In a replacement project, a face-to-face mismatch can create practical site problems. The existing pipe gap may not accept the new valve, or the pipework may need modification. A mismatch can require pipe spool adjustment, short spool pieces or support changes, especially when the valve replaces another manufacturer’s design.
This is why face-to-face length must be confirmed before ordering. For replacement projects, compare the existing valve tag, measured face-to-face length, old drawing if available, selected connection style and the new manufacturer’s drawing.
What Face-to-Face Length Controls
Face-to-face length is mainly used for:
- checking whether the valve fits between existing pipe flanges;
- preparing pipe spool or installation layout;
- comparing replacement valves;
- reviewing whether a wafer, lug or flanged design changes the installation length;
- confirming whether the selected valve follows the required project standard.
Face-to-Face vs Other Dimensions
The following comparison separates face-to-face length from other dimensions that are often confused with it during replacement or layout review.
| Dimension type | What it controls | Used for | Common mistake | Where to confirm |
|---|---|---|---|---|
| Face-to-face length | Distance between pipe connection faces | Replacement, pipe gap, layout | Treating it as the only important dimension | GA drawing or certified drawing |
| Flange data | OD, bolt circle, bolt holes and drilling | Bolting compatibility | Checking only valve size, not drilling | Flange table, drawing, standard |
| Overall height | Total height of valve assembly | Installation clearance | Ignoring actuator height | GA drawing |
| Open height | Height with gate fully open | Overhead space | Checking only closed height | GA drawing and actuator data |
| Actuator envelope | Space occupied by operator or actuator | Access and maintenance | Assuming actuator does not change dimensions | Final actuator drawing |
| Weight | Valve assembly mass | Lifting, support, shipping | Using body-only weight | Final datasheet or drawing |
Face-to-face dimensions may be influenced by standards such as MSS SP-81, EN 558 or ISO 5752, depending on project requirements and valve construction. However, the final value should still be confirmed on the manufacturer’s drawing for the exact valve model.
For a deeper standards and pressure-rating context, review the knife gate valve pressure classes and MSS-SP81 guide instead of expanding this dimensions article into a full standards page.
Flange Data, Bolt Circle, Bolt Holes and Drilling Checks
Flange data is another critical part of knife gate valve dimensions. A valve may have the correct nominal size but still fail to match the pipeline if the flange drilling, bolt-hole pattern or flange standard is different.
For RFQ and replacement work, flange data should be checked together with face-to-face length. This is especially important when the project involves different standards such as ASME Class, EN / DIN PN, JIS or customer-specific drilling.
Flange and Bolting Fields to Confirm
Key flange-related fields include:
- flange outside diameter;
- bolt circle diameter;
- number of bolt holes;
- bolt-hole diameter;
- flange drilling standard;
- connection style: wafer, lug or flanged;
- pressure class or PN rating;
- gasket contact area if relevant to the project.
Note: this section only covers dimensional compatibility. Bolt tightening sequence, gasket selection and torque values belong to the manufacturer’s installation and operation manual.
Why Connection Type Matters
Knife gate valves may be supplied in wafer, lug or flanged configurations. These connection styles can affect the valve body envelope, bolting arrangement and installation fit.
A wafer-style valve is typically installed between pipe flanges. A lug-style valve may provide threaded or lugged bolting support. A flanged knife gate valve has full flange ends. These differences can affect the dimensional checks needed before procurement.
If the project specifically requires full flange ends, the flanged knife gate valve page can support the product-level review after the dimensional checks are complete.
When sending an RFQ, do not only state “DN150 knife gate valve.” Also confirm the required connection style and flange standard. For RFQ work, confirming the connection style and flange standard early helps avoid bolt-hole mismatch or late dimensional revision.
For a broader comparison of wafer, lug, flanged, butt weld and clamped designs, see the knife gate valve connection types guide.

Overall Height, Open Height, Stroke and Actuator Envelope
For many projects, the most visible dimension problem is not the face-to-face length. It is the height and actuator envelope.
A knife gate valve has a sliding gate or blade. When the valve opens, the gate must travel upward or into the actuator assembly. This means the open height may be much greater than the closed body height. If the project has limited overhead space, the drawing must be checked carefully before ordering.
If open height or actuator envelope is not checked, the valve may fit between flanges but still fail to open fully or interfere with overhead structures, platforms or adjacent equipment.
Height and Clearance Fields
The main height and clearance fields include:
- closed overall height;
- fully open height;
- stem extension;
- stroke or gate travel;
- handwheel height and diameter;
- pneumatic cylinder length;
- electric actuator height;
- hydraulic actuator envelope;
- side clearance for operation, inspection or maintenance access;
- lifting or handling clearance if required.
Different actuator types can change the final valve dimensions. A manual handwheel, pneumatic cylinder, electric actuator and hydraulic actuator may use different height envelopes even for the same valve body size.
This section should not be turned into actuator sizing. Actuator torque, thrust and control selection belong to a separate actuator selection or sizing guide. Here, the focus is dimensional clearance.
For actuator force, control method and automation selection, use the knife gate valve actuator size and type guide rather than treating this dimensions article as an actuator sizing guide.
How to Read a Knife Gate Valve Drawing or GA Drawing
A knife gate valve drawing or GA drawing gives the dimensional information needed for layout, RFQ review and replacement. It should be read as a complete dimensional document, not only as a product picture.
A useful GA drawing should show the valve body, connection faces, flange drilling, gate or stem travel, actuator arrangement and overall envelope. These fields help engineers check layout fit, but replacement projects need one more step: the drawing should be compared with the existing valve and site dimensions.

What a GA Drawing Should Show
A knife gate valve GA drawing should usually include:
- DN / NPS;
- pressure class or PN rating;
- face-to-face length;
- flange OD;
- bolt circle;
- bolt-hole number and size;
- bore or port size;
- overall height;
- open height;
- actuator type and envelope;
- width or side clearance;
- approximate weight;
- material and seat notes if they affect construction;
- drawing revision or project reference.
These fields show whether the valve can fit the pipe, flange arrangement and available space. They do not replace site checking when an old valve is being replaced.

Drawing Checks for Replacement Projects
For replacement work, the drawing should be compared with the existing installation. Check:
- existing valve tag;
- existing face-to-face length;
- existing flange standard and drilling;
- available overhead space;
- actuator position and access;
- pipe centerline and installation space;
- whether the existing valve is wafer, lug or flanged;
- whether the new actuator changes clearance.
A drawing request is not the same as a CAD download request. A GA drawing is used to confirm engineering dimensions. CAD blocks, 3D models and downloadable resource libraries are separate topics and should not drive this article.
Datasheet, Dimension Chart and Certified Drawing: Which One Should You Use?
Datasheets, dimension charts, PDF catalogues and certified drawings do not serve the same purpose. A dimension chart can help with early comparison. A datasheet can help confirm basic construction and specification. A certified drawing is the safer reference for final layout, procurement and replacement confirmation.
Drawing and Document Differences
| Document type | Best use | Limit | When to rely on it | RFQ / procurement caution |
|---|---|---|---|---|
| Dimension chart | Early comparison of common sizes | May not reflect actuator, connection or project-specific design | Early planning only | Do not use as the only final installation reference |
| Datasheet | Basic valve specification and main dimensions | May be generic or series-based | Initial RFQ and technical screening | Confirm whether it matches the selected configuration |
| Catalogue PDF | Product range overview | May include standard or typical data only | General product understanding | Avoid treating catalogue data as certified dimensions |
| GA drawing | Layout and dimensional review | May still be preliminary before order confirmation | RFQ review, layout check, replacement review | Confirm revision and project configuration |
| Certified drawing | Final dimensional confirmation for project | Requires confirmed specification | Procurement, installation planning, replacement confirmation | Use for final approval when dimensions are critical |
A knife gate valve dimensions PDF can be useful, but it should not automatically be used for final installation. For tight layouts, replacement projects, approval drawings or custom actuator configurations, a PDF dimension chart should not be treated as the final installation reference; request a GA drawing or certified drawing for the exact configuration.

Standards and References That May Affect Knife Gate Valve Dimensions
Knife gate valve dimensions may reference several standards or project specifications. However, standards do not replace the manufacturer’s final drawing. Some standards are related to face-to-face length. Others are related to flange dimensions, drilling or pressure class.
For a neutral reference on face-to-face and centre-to-face dimensions, ISO lists ISO 5752:2021 for metal valves in flanged pipe systems, but the selected knife gate valve drawing should still control the final project dimensions.
The project requirement should define which standard applies. Project region, owner specification and piping standard may determine which reference is used.
Common Standards and Reference Areas
| Reference / standard | Where it may apply | What it does not replace | How to confirm final dimensions |
|---|---|---|---|
| MSS SP-81 | May be referenced for knife gate valve design or face-to-face boundary | Final manufacturer dimensions | Check datasheet and certified drawing |
| EN 558 | Face-to-face and end-to-end reference for industrial valves | Project-specific valve construction | Confirm selected series and connection type |
| ISO 5752 | Face-to-face / center-to-face reference for metal valves | Manufacturer-specific envelope | Confirm GA drawing |
| ASME B16.5 | Pipe flange dimensions and pressure-temperature ratings | Valve body face-to-face length | Confirm flange drilling and valve drawing |
| PN10 / PN16 | EN / DIN flange pressure rating context | Valve full dimensional package | Confirm flange data and connection style |
| ASME Class 150 | ASME flange / pressure class context | Complete valve dimensions | Confirm flange drilling and manufacturer drawing |
For flange-related fields, ASME describes ASME B16.5 pipe flanges and flanged fittings as covering flange dimensions, tolerances, pressure-temperature ratings, marking and testing, so it should support flange compatibility checks rather than replace the valve GA drawing.
A common mistake is to assume that a standard reference gives every dimension needed for a knife gate valve. In practice, the standard may help define one part of the dimensional package, while actuator envelope, height, width and project-specific construction still require manufacturer confirmation.
Even when a project references MSS SP-81, EN 558, ISO 5752 or ASME B16.5, the final face-to-face value, flange data and actuator envelope should still be confirmed on the manufacturer’s drawing.
Why Knife Gate Valve Dimensions May Change
Knife gate valve dimensions can change even when the nominal size is the same. This is why RFQ information must be complete.
For example, a DN200 knife gate valve with manual operation may not have the same overall height as a DN200 valve with a pneumatic cylinder. A wafer-style valve may require different bolting checks than a flanged type. A valve for abrasive slurry may use a different body, liner or seat arrangement that affects the envelope.
The key relationship is:
Specification field → dimension impact → RFQ risk → drawing confirmation
Specification Fields That Affect Dimensions
| Specification field | Dimension impact | RFQ risk if missing | Drawing confirmation needed |
|---|---|---|---|
| DN / NPS | Sets the basic valve size | Wrong pipe size selection | Confirm nominal size and bore |
| Pressure class / PN rating | Affects flange and body design | Incorrect flange match | Confirm flange standard and drilling |
| Connection type | Affects face, bolting and body envelope | Valve may not fit existing pipework | Confirm wafer, lug or flanged design |
| Flange standard | Affects bolt circle, hole size and OD | Bolt holes may not align | Confirm ASME / EN / DIN / JIS requirement |
| Actuator type | Affects overall height and actuator envelope | Insufficient clearance | Confirm manual, pneumatic, electric or hydraulic actuator |
| Seat design | May affect body and internal construction | Wrong replacement assumption | Confirm seat type if relevant |
| Body material / liner | May affect construction and weight | Unexpected envelope or weight | Confirm drawing revision |
| Media / service | May require special design | Wrong valve configuration | Confirm slurry, wastewater, mining or pulp service |
| Replacement tag | Helps match existing installation | New valve may not fit | Provide old valve drawing or measured dimensions |
| Certified drawing requirement | Determines final approval process | Delay in procurement or installation | Request project drawing if needed |

Missing specification fields can lead to a generic drawing, drawing revision or installation mismatch because the supplier cannot confirm the exact construction envelope.
If the specification is incomplete, the dimensional drawing may also be incomplete or unsuitable for final approval.
RFQ Checklist for Dimension and Drawing Confirmation
Before requesting confirmed knife gate valve dimensions, provide enough technical information for the supplier to identify the correct construction. The more complete the RFQ data is, the easier it is to confirm the face-to-face length, flange data, actuator envelope and certified drawing.
RFQ Data Needed for Dimension Confirmation
| Required information | Example | Why NTGD needs it | Related dimension / drawing field |
|---|---|---|---|
| DN / NPS | DN150 / NPS 6 | Confirms nominal size | Bore, face-to-face, flange data |
| Pressure class / PN | PN10, PN16, Class 150 | Confirms flange and body requirements | Flange OD, bolt circle, drilling |
| Connection type | Wafer, lug, flanged | Affects installation fit | Face / bolting / body envelope |
| Flange standard | ASME, EN, DIN, JIS | Determines drilling pattern | Bolt holes, BCD, flange OD |
| Face-to-face requirement | Existing pipe gap or project standard | Prevents replacement mismatch | F-F length |
| Actuator type | Manual, pneumatic, electric, hydraulic | Affects height and envelope | Overall height, open height |
| Media | Slurry, wastewater, pulp, dry solids | May affect valve construction | Body, seat, liner, weight |
| Temperature | Project operating data | May affect seat / material selection | Material and construction notes |
| Body / seat material | WCB, stainless steel, rubber seat, metal seat | Affects construction | Drawing notes and weight |
| Drawing type | GA drawing, certified drawing | Defines approval level | Drawing revision and dimensions |
| Replacement tag | Existing model or tag number | Helps match old installation | Replacement dimension check |
| Existing dimensions | Measured F-F, flange data, height | Reduces mismatch risk | Final drawing confirmation |

For replacement projects, photographs and field measurements can also help. However, measured dimensions should still be checked against a formal drawing before final procurement.
NTGD Knife Gate Valve can review the RFQ information and help confirm the required dimensions, datasheet or certified drawing for the selected valve configuration.
After preparing the size, pressure class, connection type, flange standard, actuator type and drawing requirement, you can contact NTGD Knife Gate Valve for dimensional review or drawing confirmation.

FAQ About Knife Gate Valve Dimensions
What dimensions are needed for a knife gate valve RFQ?
A knife gate valve RFQ should include DN / NPS, pressure class, connection type, flange standard, face-to-face requirement, actuator type, media, temperature, material, seat type and required drawing type. If it is a replacement, provide the existing valve tag, existing face-to-face length and flange data.
What is the face-to-face dimension of a knife gate valve?
The face-to-face dimension is the distance between the two pipe connection faces of the valve. It is important for pipe layout, replacement and installation fit. The final value should be confirmed from the valve drawing or certified drawing.
Are all knife gate valve dimensions the same across manufacturers?
No. Some dimensions may follow project or industry references, but not every dimension is the same across manufacturers. Face-to-face length, flange drilling and pressure class may reference standards, while actuator envelope, open height and manufacturer construction can differ by valve series and configuration.
Is MSS SP-81 used for knife gate valve dimensions?
MSS SP-81 may be relevant to certain knife gate valve design and dimensional references, depending on the project and valve type. However, it should not replace the manufacturer’s datasheet, GA drawing or certified drawing for final dimensions.
Do wafer, lug and flanged knife gate valves have the same dimensions?
Not always. Wafer, lug and flanged knife gate valves may differ in connection details, bolting arrangement, body envelope and flange data. For replacement or RFQ work, confirm the selected connection style and flange drilling before using a dimension chart.
Do actuator type and open height affect dimensions?
Yes. Manual, pneumatic, electric and hydraulic actuators can change the overall height, open height and actuator envelope. This is important when the installation has limited overhead or side clearance.
Is a PDF dimension chart accurate enough for installation?
A PDF dimension chart can be useful for preliminary review, but it should not be the only final installation reference. For procurement, replacement or tight layout conditions, request a GA drawing or certified drawing for the exact valve configuration.
Can I get a knife gate valve drawing before ordering?
In many RFQ cases, a GA drawing or preliminary drawing can be prepared after the key specification data is confirmed. For final approval, a certified drawing may be required after the configuration and order details are fixed.
Is a knife gate valve specification the same as a datasheet?
No. A specification usually describes project requirements, while a datasheet describes the selected valve data. In an RFQ workflow, the specification helps the supplier choose the correct configuration, the datasheet supports technical review, and the certified drawing confirms the final dimensional layout.
What should I send to get a certified knife gate valve drawing?
Send the DN / NPS, pressure class, connection type, flange standard, actuator type, media, temperature, material / seat requirement, replacement tag if available, and required drawing type. If replacing an existing valve, also send measured face-to-face length, flange data and installation photos.
Conclusion
Knife gate valve dimensions should be read as a complete dimensional package, not as one fixed number. Face-to-face length, flange drilling, bolt-hole pattern, overall height, open height, stroke, actuator envelope and drawing revision all affect whether the valve fits the project.
Dimension charts, datasheets and PDF catalogues are useful for early review, but they may not reflect the final selected valve configuration. For replacement, installation layout or procurement approval, the safer reference is a GA drawing or certified drawing for the exact valve model.
If you need confirmed knife gate valve dimensions for RFQ, replacement or layout review, prepare the valve size, pressure class, connection type, flange standard, actuator type, media, seat / material and required drawing type before requesting dimensional confirmation from NTGD Knife Gate Valve. Incomplete dimensional data can lead to drawing revisions, pipe modification or installation delays.